Matters needing attention during the operation of oral liquid irrigation machine

时间:2019/4/11 15:22:11
Matters needing attention during the operation of oral liquid irrigation machine
Operating processes
1, when there is an emergency, press the red "total stop" switch; Understanding of points of note;
2, insert the plug of the overpress and the machine, the air compressor operates, inflates, and waits for the machine to start;
3, after the machine starts to enter the home page, light press the home page, enter the operating interface, press the "parameter setting" to enter the setting interface, mainly adjust the "filling time", control the amount of injection, but there is no clear function relationship between the two, need to adjust themselves. 20ml is about 1.1 S and 15ml is about 0.9 S. Press "Back Home" again, click on the home page, enter the operating interface.
4, "green left" switch for the cover switch, "green right" switch for the bottle switch. Both are open. When the bottle enters the conveyor belt, press "automatic start" to start the machine.
5, there are three large switches below the operating platform, * the vibration speed of the adjustable cap holder, the second can regulate the vibration speed of the bottle cap transport track, and the third can regulate the vibration speed of the bottle cutter; "Manual operation" can control a certain part of the machine separately for testing; The transmission speed of the bottle can be controlled by the "split bottle motor", and the speed of the trim plate and turntable can be controlled by the "main motor".
Points for attention
1, bottle system: In the bottle machine, the bottle is only half loaded; In the transport track, if the bottles are stuck with each other, gently push back a bottle; On the bottle plate, if the bottle mouth is deformed, it will be possible to get stuck on the bottle plate. You need to press the "total stop" switch, stop the machine immediately, and manually go to the bottle to open the machine.
2, filling system: Before and after each test, you need to clean the infusion tube with alcohol. Remove the filling port, and use the finger to block the sensing device with the rhythm of the machine, wash the infusion tube, drain the ethanol, and then send the liquid into the infusion tube. After removing the bubbles in the tube, install the filling port.
3, pressure cover system: In the cover machine, the bottle cap is only added half, and the cover track is kept full of bottle caps, which can be stamped normally. If there is a cap, gently push the cap; If the cover track is violently shaken, reduce the "flat cover switch." Cover should be aligned with bottle mouth. If not aligned, stop the machine, remove the bottle, and then open the machine.
4, sealing system: when the amplitude change rod is lowered, the height should be about 1mm lower than the bottle mouth, using an ultrasonic seal, on the "intelligent ultrasonic generator", the ultrasonic frequency is between 1-2 grids, and the "ultrasonic test" button can be used. Test, If the overload display light is on, you need to adjust the frequency and adjust the left knob appropriately. The "Pneumatic Test" button measures the height of the amplitude bar. If the sealing is not strict, the "welding time" can be appropriately increased, but it must not be too large to make the cap melt.
5, out of the bottle structure: If the clamp is rotating while touching the turntable, and it is impossible to put the bottle on the side, then open the left machine box, loosen the screw, properly rotate the clamp, and tighten it.
6, the "Auto Start" button can not be used, see the bottom right of the display, whether the arrow points to "automatic." If you turn it on normally, but a certain part is not running, it may be damaged by the electrical appliance and need to be replaced. Pressure gauges under the machine should be maintained
0.2 MPa The interior of the machine requires frequent use of alcohol to wipe and keep it clean. Bottle and cap should be kept dry when used. Insensitivity, may be wet, wipe off.